Physical media: copper, fibre & signalling
Choose cabling and explain speed, duplex and distance limits.
By Invicly Tech, , in Computer Networking. About 11 minutes to read.
In short
The physical layer moves raw bits as electrical signals, light or radio waves. Copper twisted pair is cheap and common up to 100 metres, while fibre carries data much further with no electrical interference. Duplex settings and cable category limit the speed a link can reach.
Explained simply
Everything on a network ends up as a physical signal: tiny changes in voltage on copper wire, flashes of light in glass fibre, or radio waves through the air. The physical layer is the part of networking that deals with these signals, the cables and the connectors.
Most office and home cables are twisted pair copper with RJ45 plugs. Inside are four pairs of thin wires, each pair twisted together to cancel out electrical noise. Better cable categories, such as Cat 6A, can carry faster signals, but every copper run is limited to 100 metres.
Fibre optic cable sends light through a thin strand of glass. It goes much further than copper, from hundreds of metres to many kilometres, and it is not affected by electrical noise or lightning. It is used between buildings, inside data centres and for internet backbones.
Duplex describes the direction of traffic. Full duplex means a device can send and receive at the same time, like a phone call. Half duplex means only one side can talk at a time, like a walkie-talkie. Modern switched links are full duplex, and both ends must agree, or the link becomes slow and full of errors.
Press Play on a diagram to walk through it one step at a time.
- Up to 100 m per run
- 1 Gbps on Cat 5e, 10 Gbps on Cat 6A
- Cheap, RJ45 connectors
- Can carry PoE power
- Hundreds of metres
- Within buildings and data centres
- Cheaper optics
- Immune to EMI
- Tens of kilometres
- Campus and long haul
- Narrow core, laser optics
- Highest capacity
- 802.3af (PoE)
- 15.4 W at the switch
- IP phones, simple cameras
- 802.3at (PoE+)
- 30 W at the switch
- Wi-Fi access points, PTZ cameras
- 802.3bt Type 3
- 60 W at the switch
- Wi-Fi 6E and 7 APs, small displays
- 802.3bt Type 4
- 90 W at the switch
- Laptops, lighting, kiosks
In depth
Copper categories and what they really support
A cable category is a promise about the signal frequency the cable handles over 100 metres. Cat 5e is rated to 100 MHz and carries 1 Gbps (1000BASE-T), and also 2.5 Gbps (2.5GBASE-T) over the full 100 m. Cat 6 is rated to 250 MHz; it supports 10 Gbps (10GBASE-T), but only up to about 55 metres. Cat 6A is rated to 500 MHz and carries 10 Gbps over the full 100 m, so it is the usual choice for new office cabling. Cat 8 reaches 25 or 40 Gbps, but only for 30 m runs inside data centres.
The 100 m limit is the whole channel: about 90 m of fixed cable in the wall plus up to 10 m of patch cords at both ends. Gigabit and faster use all four pairs, so a cable with one broken pair may still link up, but only at 100 Mbps.
- Cat 5e: 1 Gbps, 2.5 Gbps at 100 m
- Cat 6: 10 Gbps up to about 55 m
- Cat 6A: 10 Gbps at 100 m
- Cat 8: 25 or 40 Gbps up to 30 m
- Linked at 100 Mbps on a gigabit port? Suspect a bad pair
Single-mode and multimode fibre
Multimode fibre has a wide core (50 micrometres for OM3, OM4 and OM5) so light bounces along many paths, or modes. Those paths have slightly different lengths, so pulses smear out over distance, which limits reach. It uses cheap 850 nm optics: 10GBASE-SR reaches 300 m on OM3 and 400 m on OM4. Multimode jackets are usually aqua (OM3, OM4) or orange (older OM1, OM2).
Single-mode fibre has a core of about 9 micrometres, so light takes essentially one path. Pulses stay sharp for tens of kilometres: 10GBASE-LR reaches 10 km at 1310 nm. Its jackets are usually yellow. The optics, called transceivers, plug into switch slots: SFP for 1 Gbps, SFP+ for 10, SFP28 for 25 and QSFP28 for 100 Gbps. Both ends must use matching optics and the right fibre type, or the link stays dark.
- 50 micrometre core, many light paths
- 850 nm, cheaper optics
- 10G-SR: 300 m (OM3), 400 m (OM4)
- Aqua jacket, inside buildings
- About 9 micrometre core, one path
- 1310 or 1550 nm lasers
- 10G-LR: 10 km, longer with other optics
- Yellow jacket, campus and long haul
Autonegotiation and the duplex mismatch trap
When you plug in a copper cable, both ends exchange pulses to agree on the fastest common speed and on full duplex. This is autonegotiation, and 1000BASE-T requires it. Trouble starts when someone forces speed and duplex on one end only. The other end, still autonegotiating, gets no answer, detects the speed, but must assume half duplex.
Now one side sends whenever it likes (full duplex), while the other stops and retries when it hears traffic (half duplex, using CSMA/CD). The link stays up and ping works, but anything heavy crawls. The full-duplex side counts CRC errors and runts (frames cut short); the half-duplex side counts late collisions. The fix is to set both ends to autonegotiate, or force both the same way.
- 1End A forced
100 Mbps full duplex, no negotiation
- 2End B autonegotiates
Hears no negotiation pulses
- 3B detects speed
Senses 100 Mbps, assumes half duplex
- 4Traffic flows
A sends freely, B backs off on collisions
- 5Symptoms
A: CRC errors. B: late collisions. Slow
Reading interface counters
Physical problems leave fingerprints in interface counters. On Linux, ip -s link show eth0 shows RX and TX packets, errors and drops, and ethtool -S eth0 shows the card's detailed counters, such as rx_crc_errors. On Cisco, show interfaces lists input errors, CRC, runts, giants and late collisions.
Read counters as a rate, not a total. A few hundred CRC errors over six months of uptime may be one old event. CRC errors that rise every minute mean a live problem: a damaged cable, a dirty fibre connector, a failing transceiver or electrical noise. Clear or note the counters, wait, and check again. Drops without errors usually mean congestion or a full buffer, not a physical fault.
- CRC errors rising: cable, connector or optic
- Late collisions: duplex mismatch or cable too long
- Drops but no errors: congestion or buffers
- ethtool -m eth0 reads optic light levels on supported cards
Learn it in 4 short steps
About 30m each. Track them with a timer in your plan.
- 1Compare twisted pair cable categories~30m
- 2Compare single-mode and multimode fibre~30m
- 3Explain full and half duplex~30m
- 4Read link speed and errors on an interface~30m
Key points
- Full duplex sends and receives at once; half duplex shares the medium.
- Duplex mismatches cause slow links with many errors.
- Speed and duplex are negotiated automatically by autonegotiation.
- Rising CRC error counters point to bad cables or connectors.
Key terms
Tap a card to flip it. 0/4 known
Examples
ethtool eth0 | grep -E 'Speed|Duplex|Link detected'
ip -s link show eth0 # RX/TX errors and dropsA server that links at 100 Mbps instead of 1 Gbps
Backups suddenly take ten times longer. Step 1: ethtool shows Speed: 100Mb/s, Duplex: Full. Step 2: the switch port and server NIC both support 1000 Mbps, so the link negotiated down. Step 3: gigabit needs all four pairs, while 100 Mbps needs only two, so a broken pair is the prime suspect. Step 4: you replace the patch cord, and the link comes up at 1000Mb/s. Step 5: if it still fails, test the wall cable with a cable tester, because one pair is likely damaged in the run.
ethtool eth0 | grep -E 'Speed|Duplex|Auto-negotiation'
# Speed: 100Mb/s Duplex: Full Auto-negotiation: on
ethtool eth0 | grep -A3 'Link partner advertised link modes'
ip -s link show eth0Spotting a flaky cable from counters
A user complains of random slowness. Step 1: read the RX errors for the interface and note the number. Step 2: wait one minute while the user works and read again. Step 3: the CRC counter jumped from 1,204 to 1,390, so errors are happening now. Step 4: because a frame with a bad CRC is dropped, TCP must resend it, which causes the slowness. Step 5: you reseat or replace the cable. Errors stop rising, and the problem is gone.
ethtool -S eth0 | grep -iE 'crc|err'
sleep 60
ethtool -S eth0 | grep -iE 'crc|err'
# Cisco equivalent:
# show interfaces gi1/0/5 | include CRC|collisionQuick reference
- Copper Ethernet: 100 m channel max (90 m fixed + 10 m patch cords)
- Cat 5e = 1 Gbps, Cat 6A = 10 Gbps at 100 m, Cat 6 = 10 Gbps only to about 55 m
- Multimode: aqua, 850 nm, hundreds of metres. Single-mode: yellow, kilometres
- Never force speed or duplex on just one end of a link
- ethtool eth0 shows speed, duplex and link; ethtool -S shows error counters
- Gigabit uses all 4 pairs; a link stuck at 100 Mbps often means a bad pair
- PoE budgets at the switch: 15.4 W (af), 30 W (at), 60 or 90 W (bt)
Quick quiz
Pick an answer to see if you're right and why.
Practice exercises
Try each one yourself first. Use the hint if you get stuck, then compare with the solution.
- Exercise 1easy
Check the speed, duplex and link status of your main wired interface, and read its error counters.
- Exercise 2medium
Plan cabling for three needs: desks 70 m from the switch at 1 Gbps, a storage server 40 m away at 10 Gbps, and a building 2 km away at 10 Gbps.
- Exercise 3hard
A Cisco port shows many runts and CRC errors, while the connected server shows late collisions. Explain the cause and give the fix commands for both ends.
Check yourself
Answer in your head, reveal, then be honest with yourself.
Feel confident about this topic?
Frequently asked questions
- Is Cat 6 worth it over Cat 5e for a home?
- For gigabit, Cat 5e is enough. Cat 6 or 6A gives room for 2.5, 5 or 10 Gbps later, and the extra cost is small compared with re-cabling walls.
- Can I use a longer Ethernet cable than 100 m?
- It may link up, but it is out of spec and errors are likely. Put a switch in the middle, or use fibre for long runs.
- Why is fibre immune to interference?
- It carries light in glass, not electricity in metal, so nearby motors, power cables and lightning cannot induce noise in it. That also makes it safe between buildings with different electrical grounds.
- What do I do if a fibre link will not come up?
- Check that both optics match (same speed and wavelength, SR to SR or LR to LR), that the fibre type matches the optics, that the strands are not swapped (transmit must reach the other side's receive) and that the connectors are clean.